Generator set data sheet
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 283kW prp
- Manufacturer: SCANIA
- Model: DC09.320A(02.64)
- Engine Type: 4-stroke diesel
- Injection Type: Direct
- Aspiration Type: Turbocharged
- Number of cylinders and arrangement: 5-L
- Bore and Stroke: 130 x 140 mm
- Displacement: 9,3 L
- Cooling System: Coolant
- Lube Oil Specifications: ACEA E6, ACEA E9, API CJ-4
- Compression Ratio: 19:1
- Fuel Consumption 100% PRP: 67,09 l/h
- Fuel Consumption 75 % PRP: 50,83 l/h
- Fuel Consumption 50 % PRP: 34,06 l/h
- Lube oil consumption with full load: 0,2
- Total oil capacity: 36 L
- Total coolant capacity: 37 L
- Governor Type Electrical
- Air Filter Type Dry
- DEF Tank
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Water separator filter (visible level)
- Dry air filter
- Radiator with pusher fan
- Radiator water level sensor
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: STAMFORD
- Model: S4L1D.E41
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-1 14"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - SOUNDPROOFED VERSION.
- Steel chassis
- Tilting cap in the exhaust
- Chassis with integrated fuel tank
- Fuel level gauge
- External emergency stop switch
- Bodywork made from high quality steel plate
- High mechanical strength
- Soundproofing provided by high-density volcanic rock wool
- Full access for maintenance (water, oil and filters, no need to remove the canopy)
- Reinforced lifting hooks for crane hoisting
- Chassis drain plug
- Oil sump extraction kit
- 3 way valve for external fuel supply (available in 1/2" and 3/8" fittings) (Optional)
- Fuel tank drain plug (Optional)
- Fuel transfer pump (Optional)
- Emergency stop button (double emergency stop protection: Interior on the panel + Exterior on the bodywork) (Optional)
- - ELECTRICAL SYSTEM.
- M5 control panel with electronic CEM7 control unit and switched emergency stop
- Power panel with built-in circuit breaker plates
- Safety relay in output terminal board (thermal magnetic trip and alarm in control unit)
- Battery Switch
- Socket boxes with 2x16A (2Ph), 1x16A (3Ph), 1x32A (3Ph) y 1x63A (3Ph)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 477 ºC
- Maximum allowed back pressure: 296 mbar
- Exhaust Flange Size (external diameter): 140 mm
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 1109,2 m3/h
- Cooling Air Flow: 4,6 m3/s
- Alternator fan air flow: 0,8 m3/s
- - STARTING SYSTEM.
- Starting power: 6 kW
- Starting power: 8,16 CV
- Recommended battery: 50 x 2 Ah
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- Fuel Tank: 910 L
- - DIMENSIONS.
- Length: 4.430 mm
- Height: 2.400 mm
- Width: 1.700 mm
- Maximum shipping volume: 18,07 m3
- Weight with liquids in radiator and sump: 5.100 kg
- Fuel tank capacity: 910 L
- Autonomy: 18 Hours
- Sound pressure level: 68 ± 2,4 dB(A)@7m
Length (A)443174.41
Width (B)17066.93
Height (C)24094.49
Weight with fluids in radiator and crankcase
5100
11245.5