Generator set data sheet
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 842kW prp ; 941kW standby
- Manufacturer: PSI
- Model: 53L
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 16-V
- Bore and Stroke: 150 x 185 mm
- Displacement: 52,3 L
- Cooling System: Coolant
- Lube Oil Specifications: SAE 15W40; API CD or CE
- Compression Ratio: 10,5:1
- Fuel Consumption ESP: 2688 kW
- Fuel Consumption 100% PRP: 2442 kW
- Fuel Consumption 75 % PRP: 1900 kW
- Fuel Consumption 50 % PRP: 1374 kW
- Fuel Consumption 25 % PRP: 866 kW
- Total oil capacity: 171 L
- Total coolant capacity: 248 L
- Governor Type Electrical
- Air Filter Type Dry
- Natural Gas engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECO43.1M4A
- Poles: 4
- Connection type (standard): Star - Parallel
- Mounting type: S-0 18''
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Emergency stop button
- Steel chassis
- Steel industrial silencer -15db(A) attenuation
- Steel residential silencer -35db(A) attenuation.
- - GAS RAMP.
- Manual shut-off valve
- Gas filter
- Double solenoid valve
- Primary pressure regulator
- Secondary pressure regulator (Zero pressure regulator)
- Low pressure switch
- High pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- High pressure regulator (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Battery Switch
- External power supply is required for remote radiator
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 625 ºC
- Exhaust Gas Flow: 150 m3/min
- Maximum allowed back pressure: 13 kPa
- - NECESSARY AMOUNT OF AIR.
- Alternator fan air flow: 1,5 m3/s
- - STARTING SYSTEM.
- Starting power: 10 x 2 kW
- Starting power: 13,6 x 2 CV
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Natural Gas
Length (A)00.00
Width (B)00.00
Height (C)00.00
Weight with fluids in radiator and crankcase
0
0