Generator set data sheet
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 70,8kW prp ; 78,8kW standby
- Manufacturer: FORD
- Model: WSG873
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Carburization
- Aspiration Type: Natural
- Number of cylinders and arrangement: 8-V
- Bore and Stroke: 107,2 x 101 mm
- Displacement: 7,3 L
- Cooling System: Liquid (water + 50% glycol)
- Lube Oil Specifications: API ≥SM, SAE 5W30
- Compression Ratio: 10,5
- Total oil capacity including tubes, filters 7,5 L
- Governor Type Electrical
- Air Filter Type Dry
- LPG-liquefied petrol gas engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: STAMFORD
- Model: UCI224G
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-3 11"1/2
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Anti-vibration shock absorbers
- Steel industrial silencer -15db(A) attenuation
- Steel residential silencer -35db(A) attenuation. (Optional)
- - GAS RAMP.
- Gas filter
- Double solenoid valve
- High pressure regulator
- Low pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- High pressure switch (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Exhaust Gas Flow: 14,17 m3/min
- Maximum allowed back pressure: 20,32 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 279,225 m3/h
- Alternator fan air flow: 0,216 m3/s
- - STARTING SYSTEM.
- - FUEL SYSTEM
- Fuel Oil Specifications: LPG
- - DIMENSIONS.
- Length: 2.100 mm
- Width: 900 mm
Length (A)21082.68
Width (B)9035.43
Height (C)00.00
Weight with fluids in radiator and crankcase
0
0