Region EUROPE

    Power Solutions

    HP RANGE

    HP RANGE

    Frequency
    Power
    Power range
     
    Version
    Model: HGP-880 T6 NG Soundproof 20FT-HC
    Model: HGP-880 T6 NG Open Skid Estático Estándar

    Model

    HGP-880 T6 NG

    HGP-880 T6 NG | Three phase | Natural Gas | Open Skid

    Model

    Powered by PSI

    Alternator STAMFORD

    Emissions Cumple EPA

    PRP
    ESP
    COP
    Power kVA
    875
    1038
    Power kW
    700
    831
    Generator set data sheet
    • Engine Specifications 1.800 r.p.m.
    • Rated Engine Output: 740kW prp ; 880kW standby
    • Manufacturer: PSI
    • Model: 40L
    • Engine Type: 4-stroke Otto Cycle
    • Injection Type: Direct
    • Aspiration Type: Turbocharged and after-cooled
    • Number of cylinders and arrangement: 12-V
    • Bore and Stroke: 150 x 185 mm
    • Displacement: 39,2 L
    • Cooling System: Coolant
    • Lube Oil Specifications: SAE 15W40; API CD or CE
    • Compression Ratio: 10,5:1
    • Fuel Consumption ESP: 2710 kW
    • Fuel Consumption 100% PRP: 2336 kW
    • Fuel Consumption 75 % PRP: 1805 kW
    • Fuel Consumption 50 % PRP: 1294 kW
    • Fuel Consumption 25 % PRP: 795 kW
    • Total oil capacity: 146 L
    • Total coolant capacity: 172 L
    • Governor Type Electrical
    • Air Filter Type Dry
    • Natural Gas engine
    • 4-stroke cycle
    • Water-cooled
    • Radiator with pusher fan
    • HTW sender
    • LOP sender
    • Electronic governor
    • Hot parts protection
    • Moving parts protection
    • Generator: STAMFORD
    • Model: S6L1D.C4
    • Poles: 4
    • Connection type (standard): Star-series
    • Mounting type: S-0 18''
    • Insulation: H class
    • Enclosure (according IEC-34-5): IP23
    • Exciter system: Self-excited, brushless
    • Voltage regulator: A.V.R. (Electronic)
    • Bracket type: Single bearing
    • Coupling system: Flexible disc
    • Coating type: Standard (Vacuum impregnation)
    • - OPEN SET VERSION.
    • Emergency stop button
    • Steel chassis
    • Anti-vibration shock absorbers
    • Steel industrial silencer -15db(A) attenuation
    • Steel residential silencer -35db(A) attenuation.
    • - GAS RAMP.
    • Manual shut-off valve
    • Gas filter
    • Double solenoid valve
    • High pressure regulator
    • Primary pressure regulator
    • Low pressure switch
    • High pressure switch
    • Valve (tightness) testing system
    • Inlet pressure manometer
    • Outlet pressure manometer
    • Special Start/Stop sequence
    • - ELECTRICAL SYSTEM.
    • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
    • Battery Switch
    • Adjustable earth leakage protection (time & sensitivity) standard in M12, with thermal magnetic protection
    • Battery charger (standard on gensets with automatic control panels)
    • Heating resistor (standard on sets with automatic control panels)
    • Starter battery/ies installed (cables and bracket included)
    • Ground connection electrical installation with connection ready for ground spike (not supplied)
    • - EXHAUST SYSTEM.
    • Maximum exhaust temperature: 670 ºC
    • Exhaust Gas Flow: 139 m3/min
    • Maximum allowed back pressure: 13 kPa
    • - NECESSARY AMOUNT OF AIR.
    • Intake air flow: 2700 m3/h
    • Alternator fan air flow: 1,76 m3/s
    • - STARTING SYSTEM.
    • Starting power: 10 kW
    • Starting power: 13,6 CV
    • Recommended battery: 75 x 4 Ah
    • Auxiliary Voltage: 24 Vdc
    • - FUEL SYSTEM
    • Fuel Oil Specifications: Natural Gas
    • - DIMENSIONS.
    • Length: 4.500 mm
    • Height: 2.400 mm
    • Width: 2.200 mm
    • Maximum shipping volume: 23,76 m3

    Dimensions

    Dimensions
    Length (A)450177.17
    Width (B)22086.61
    Height (C)24094.49

    Weight

    Weight

    Weight with fluids in radiator and crankcase

    0

    0

    Fuel capacity

    0

    0

    Request a Quote

    Request a Quote

    By filling in this form you consent to have your information processed and recorded on our system and for the management of your relationship as a user, client, or candidate for employment Himoinsa.com.
    /privacy-policy/eng.html

     privacy policy *
    * Required fields
    COMPARE
    Compare
     

    Necessary

    Technical cookies are strictly necessary for our website to function and to be able to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not required in this regard.

    Statistics

    The analysis cookies allow us to study the navigation of the users of our website in general (for example, which sections of the page are the most visited, which services are used the most and if they work correctly, etc.). Based on the statistical information on navigation on our website, we can improve both the operation of the page itself and the different services it offers. Therefore, these cookies do not have an advertising purpose, but only serve to make our website work better, adapting to our users in general. By activating them you will contribute to this continuous improvement.

    Marketing

    Marketing cookies are used to track visitors on web pages. The intention is to show ads relevant and attractive to the individual user, and therefore more valuable to publishers and third-party advertisers.